SECURITRON MODEL DK-26 DIGITAL KEYPAD
TABLE OF CONTENTS AND GUIDE TO THIS MANUAL
The DK-26 is a powerful and versatile product with many features and modes of operation. In
most applications you will use only some of these features so this table of contents includes a
description of the type of application that applies to each different section. By studying it first,
you can save considerable time by skipping over those parts of the manual that don't apply to
your application.
SECTION 1. DESCRIPTION --------------------------------------------------------------------Page 1
SECTION 2. PHYSICAL INSTALLATION---------------------------------------------------Page 1
SECTION 3. WIRING------------------------------------------------------------------------------Page 3
SECTION 3.1 POWER SELECTION----------------------------------------------------------Page 3
This section explains the power that must be used and gives you power consumption
figures.
SECTION 3.2 CONNECTING THE KEYPAD CABLE TO THE CPU BOARD -----Page 3
SECTION 3.3 POWER AND ELECTRIC LOCK WIRING--------------------------------Page 3
This section introduces the different basic wiring schemes generally required for electric
strike control (no exit switch needed). The three sections below provide separate drawings
and descriptions depending on your power source and on the power required by the lock.
SECTION 3.3.1 AC LOCK WITH AC POWER ---------------------------------------------Page 3
SECTION 3.3.2 DC LOCK WITH AC POWER ---------------------------------------------Page 5
SECTION 3.3.3 DC LOCK WITH DC POWER ---------------------------------------------Page 6
SECTION 3.4 USE OF THE “F” TERMINAL -----------------------------------------------Page 7
The “F” terminal is mainly used for convenient connection of fire alarm contacts which will
release a fail safe lock in the event of activation of the fire alarm.
SECTION 3.5 ADDING OTHER LOCK CONTROL SWITCHES-----------------------Page 7
This section and drawing show proper connection for an external switch such as from
Securitron’s Lock Control Panel.
SECTION 3.6 THE REX FUNCTION----------------------------------------------------------Page 8
When you are using a magnetic lock or solenoid bolt, you often require a separate switch to
allow egress. This switch can be connected to the CPU board to provide timed egress in
different ways. This section fully covers this requirement.
SECTION 4. PROGRAMMING -----------------------------------------------------------------Page 10
SECTION 4.1 FIXED PROGRAMMING ------------------------------------------------------Page 10
Fixed programming is for lower security applications when the code is not expected to need
regular changing by the user. The “Hard” code is used for this requirement.
Seitenansicht 0
1 2 3 4 5 6 ... 29 30

Inhaltsverzeichnis

Seite 1 - Rev. A.2, 10/03

© Copyright, 2003, all rights reserved • Securitron Magnalock Corp., 550 Vista Blvd., Sparks NV 89434, USA Tel: (775) 355-5625 • (800) MAGLOCK • Fax:

Seite 2 - Rev. A.2. 10/03

Rev. A.2, 10/03 Page-7 FIG 5: DC LOCK - DC POWER WIRING NC1 C1 NO1AC IN FDC IN /OUT+POWER SUPPLY12 OR 24 VDCDC FAIL SECUREOR FAIL SAFE LOCKMOVIF

Seite 3

Rev. A.2, 10/03 Page-8 lock and if it’s fail secure, the switch will need to send power to the lock. Figure 6 shows how to add external contacts f

Seite 4 - 2. PHYSICAL INSTALLATION

Rev. A.2, 10/03 Page-9 When using exit switches, the possibility must be considered that an electronic failure may occur to the DK-26 and a person

Seite 5 - Rev. A.2, 10/03 Page-2

Rev. A.2, 10/03 Page-10 FIG. 8: DOUBLE BREAK WIRING FOR FREE EGRESS (SPDT SWITCH) 4. PROGRAMMING The DK-26 has ten numbered keys and a bell key

Seite 6 - 3. WIRING

Rev. A.2, 10/03 Page-11 "traffic control" applications, as the longer the code remains unchanged, the greater the risk that an unauthoriz

Seite 7 - Rev. A.2, 10/03 Page-4

Rev. A.2, 10/03 Page-12 codes to be certain that the unit will operate only on the single code you plan to enter. Follow the steps shown below.

Seite 8 - AC FAIL SECURE

Rev. A.2, 10/03 Page-13 After you’ve completed your entries, test your user and program codes by entering them. The user code should open the door

Seite 9 - Rev. A.2, 10/03 Page-6

Rev. A.2, 10/03 Page-14 Enter program code, followed by the Bell Key, note rapid yellow flashing LED (program mode) Enter prefix 0-1 followed

Seite 10 - Rev. A.2, 10/03 Page-7

Rev. A.2, 10/03 Page-15 button in the CPU board. It is deliberately kept separate from all programming functions. Another use for it, however, is

Seite 11 - Rev. A.2, 10/03 Page-8

Rev. A.2, 10/03 Page-16 To delete all User codes, there is a special prefix. Put the unit into program mode (fast yellow flash) from the “Prgm Cod

Seite 12 - Rev. A.2, 10/03 Page-9

Rev. A.2. 10/03 SECTION 4.2 KEYPAD CHANGEABLE PROGRAMMING-----------------------------Page 12 This section explains how to set up easy code change

Seite 13 - 4. PROGRAMMING

Rev. A.2, 10/03 Page-17 To return the red/green LED logic to factory set default, put the unit into program mode and enter 7-4. 6. USE OF THE PROG

Seite 14 - Rev. A.2, 10/03 Page-11

Rev. A.2, 10/03 Page-18 6.3 ANTI-TAMPER ALARM FUNCTION A person attempting to guess the code and pressing 16 wrong digits will put the DK-26 into

Seite 15 - Rev. A.2, 10/03 Page-12

Rev. A.2, 10/03 Page-19 6.5 NIGHTLIGHT FUNCTION When this function is selected, the act of touching any key will operate the programmable relay fo

Seite 16 - Rev. A.2, 10/03 Page-13

Rev. A.2, 10/03 Page-20 7.3 ALARM SYSTEM SHUNTING The DK-26's lock control relay is of the double pole, double throw type. Note that in all

Seite 17 - Rev. A.2, 10/03 Page-14

Rev. A.2, 10/03 Page-21 Put the unit into program mode and enter 8-0 to assign this function to the HCD terminal or 8-1 to assign it to the UCD ter

Seite 18 - Rev. A.2, 10/03 Page-15

Rev. A.2, 10/03 Page-22 MAGNACARE® LIMITED LIFETIME WARRANTY SECURITRON MAGNALOCK CORPORATION warrants that it will replace at customer’s request,

Seite 19 - Rev. A.2, 10/03 Page-16

Rev. A.2, 10/03 Page-i APPENDIX A: COMMAND SUMMARY WITH THE UNIT IN PROGRAM MODE (FAST YELLOW FLASH): 00 followed by 5-7 digits sets Program code

Seite 20 - DOORBELL

Rev. A.2, 10/03 Page-ii APPENDIX B: TROUBLESHOOTING Note first that the DK-26 replaces older Securitron keypads: the DK-20, DK-20+ and DK-25. The

Seite 21 - AUDIBLE DOOR PROP ALARM

Rev. A.2, 10/03 Page-iii If PolySwitch #1 has tripped, visually inspect the four large diodes on the board to see if a loose wire has fallen on the

Seite 22 - Rev. A.2, 10/03 Page-19

Rev. A.2, 10/03 Page-iv entry will be ignored. Finally note that if terminals SRC and UCD are connected, all User codes will be disabled. If term

Seite 23 - Rev. A.2, 10/03 Page-20

Rev. A.2. 10/03 SECTION 6.3 ANTI-TAMPER ALARM FUNCTION ---------------------------------Page 18 Someone entering 16 wrong digits while attempting

Seite 24 - Rev. A.2, 10/03 Page-21

Rev. A.2, 10/03 Page-v PROBLEM-- How to check the Keypad For reference, when each key is pressed, two terminals will measure zero volts with respec

Seite 25 - LIMITED LIFETIME WARRANTY

Rev. A.2, 10/03 Page-1 SECURITRON MODEL DK-26 DIGITAL KEYPAD INSTALLATION & OPERATING INSTRUCTIONS 1. DESCRIPTION Securitron's DK-26 is

Seite 26 - APPENDIX A: COMMAND SUMMARY

Rev. A.2, 10/03 Page-2 FIG. 1: PHYSICAL INSTALLATION OF KEYPAD MOUNTINGSURFACE(1) MOUNT SCREW TO ENGAGE SLOT ATTOP OF KEYPADDRILL 1/8" (3MM)

Seite 27

Rev. A.2, 10/03 Page-3 3. WIRING 3.1 POWER SELECTION The DK-26 operates on 12 to 24 volts AC or DC. Nearly all electric locks operate on voltage

Seite 28

Rev. A.2, 10/03 Page-4 FIG. 2: OVERVIEW OF CPU BOARD SRCREXUCD HCD NCX CXNOXNC2 C2NO2NC1 C1NO1GRN YEL RED BLUWHTBLK GRY BRN BGE ORG PNKVIOAC IN F

Seite 29

Rev. A.2, 10/03 Page-5 Note installation of the MOV across the power wires to the lock. The MOV is the small black disk shaped component furnished

Seite 30 - IF THE PROBLEM PERSISTS

Rev. A.2, 10/03 Page-6 reduce the switching life of the relay. The arc also creates electronic noise which could cause the microprocessor to malfu